AA 1993 Standard Reference Detergent WOB – 24LB
/ Bucket1993 AATCC Standard Detergent WOB (without optical brightener) is used in AATCC Test Method 61 to evaluate the washfastness of fabrics. Detergent is provided in a 24 lb bucket.
Showing 17–27 of 27 results

1993 AATCC Standard Detergent WOB (without optical brightener) is used in AATCC Test Method 61 to evaluate the washfastness of fabrics. Detergent is provided in a 24 lb bucket.

Multifiber Fabric #10, is a multifiber fabric with approximately 8 mm (0.33 inch) filling stripes of 6 fibers, acetate, bleached cotton, nylon, polyester, acrylic, and worsted wool yarns, woven on a warp of filament polyester. Available as 2″x4″ precut pieces with cold cut edges. Multifiber Fabric #10 with cold cut edges should only be used in static AATCC colorfastness tests. Cold cut multifiber fabrics have a clean level edge. In AATCC colorfastness testing, cold cut multifiber fabrics are used to evaluate potential staining of a test sample on other textiles in stationary colorfastness testing scenarios. Multifiber fabric with cold cut edges will fall apart if they are used with agitation or in a laundrometer under mechanical action.

1993 Standard Reference Detergent is manufactured to AATCC specifications and DOES contain optical brighteners. Provided in a 24 lb bucket.


AATCC 1993 Standard Reference Powder Detergent WITH optical brighteners in 1 Kg special Bucket to withstand High Temperatures.

Multifiber Fabric #10 is a multifiber fabric with approximately 8 mm (0.33 inch) filling stripes of 6 fibers, acetate, bleached cotton, nylon, polyester, acrylic, and worsted wool yarns, woven on a warp of filament polyester.
Available as 2″x2″ precut pieces, Multifiber Fabric #10 with overcast serged edges are heat sealed along the waste stripes and overcast stich serged along the filling stripes. This type of added edge finish prevents fraying and gives the multifiber test piece added stability. It can be used in rigorous colorfastness testing situations and is recommended for any tests that subject the multifiber fabric to increased agitation and movement.
In AATCC colorfastness testing, heat sealed and overcast serged multifiber fabrics are used primarily to evaluate potential staining of a dyed or printed test sample on other textiles in wash tests where the test material experiences agitation and movement during the testing process. Multifiber fabrics with heat sealed edges should not be used in stationary tests because the raised melted edge can cause uneven staining between the multifiber fabric and test specimen.

AATCC 1993 Standard Reference Powder Detergent WITHOUT optical brighteners Drum


AATCC 1993 Standard Reference Powder Detergent WITH optical brighteners in 10 Kg special Bucket to withstand High Temperatures.


AATCC 1993 Standard Reference Powder Detergent WITH optical brighteners in 5 Kg special Bucket to withstand High Temperatures.


AATCC 1993 Standard Reference Powder Detergent WITHOUT optical brighteners in 5 Kg special Bucket to withstand High Temperatures.


AATCC 1993 Standard Reference Powder Detergent WITHOUT optical brighteners in 10 Kg special Bucket to withstand High Temperatures.

Multifiber Fabric #10 is a multifiber fabric with approximately 8 mm (0.33 inch) filling stripes of 6 fibers, acetate, bleached cotton, nylon, polyester, acrylic, and worsted wool yarns, woven on a warp of filament polyester.
Available as 2″x4″ precut pieces, Multifiber Fabric #10 with heat sealed edges can be used in dynamic AATCC colorfastness tests that involve agitation and movement of the test pieces. Heat Sealed multifiber fabrics have a melted or fused edge, which reduces fraying and increases stability in the multifiber fabric test fabric.
In AATCC colorfastness testing, heat sealed multifiber fabrics are used primarily to evaluate potential staining of a dyed or printed test sample on other textiles in wash tests where the test material experiences agitation and movement during the testing process. Multifiber fabrics with heat sealed edges should not be used in stationary tests because the raised melted edge can cause uneven staining between the multifiber fabric and test specimen, and results cannot be guaranteed.
End of content
End of content
Our team can help you source the right solution for your application.
Request Product InformationGlobal support. Local expertise.
Testfabrics, Inc.
+1 570-603-0432
info@testfabrics.com
415 Delaware Avenue West Pittston, Pa 18643
Made in the USA
Our multifiber products are made in Pennsylvania and trusted
worldwide.
48 Agents Worldwide
Need local support? We’ll connect you
to your nearest agent.

© 2026 Testfabrics. All Rights Reserved.
No products in the cart.